The CMDR Tethered System offers superior image resolution for diagnostic imaging. This portable digital radiography system includes a tethered digital detector (DR) and laptop mounted on a two-wheel, stainless steel stand, providing easy and convenient transport for the entire system. The digital detector slips out of its onboard protective enclosure for use. The CMDR Tethered System is your complete, portable radiography solution for your practice and in the field.
FEATURES
The CMDR Tethered System is a complete portable digital radiography system featuring a tethered Cesium digital detector integrated with either a MinXray HF100H+ or the HF120/60HPPWV PowerPlus™ portable x-ray unit. The system easily moves on its two-wheel stand and the digital detector slips out of its protective sleeve for a quick set up in less than one minute. The CMDR Tethered System provides the following features:
Rugged construction yet light and compact
Easily transportable between sites
Sets up for operation in less than 1 minute
Image acquisition in less than 10 seconds
Superior resolution
System Net Weight: Approximately 147 lb (67kg)
PRODUCT SPECS
MinXray HF120/60HPPWV PowerPlus™
X-Ray Output: 3 kW at 100 kV, 60-14 mA @40-120 kVDC
​
Input Line Voltage: 100-260 VAC, 50/60 Hz
​
Total Filtration with Collimator: 3.2 mm AI Equivalent
MinXray HF100H+
X-Ray Output: 2 kW at 100 kV, 30-20 mA @40-100kVDC
​
Input Line Voltage: 100-140 or 200-260 VAC, 50/60 Hz
​
Total Filtration with Collimator: 3.2 mm AI Equivalent
MinXray HF1202
X-Ray Output: 4 kW at 100kV, 60-13.8 mA @40-120kVDC
​
Input Line Voltage: 120-260 VAC, 50/60 Hz
​
Total Filtration with Collimator: 3.2 mm AI Equivalent
ATX QUANTpower 400 – for international sales only
X-Ray Output: 6 kW at 100 kV, 100-50 mA (max) @40-120 kVDC
​
Input Line Voltage: 210-260 VAC, 50/60 Hz, 16 A
​
Total Filtration with Collimator: 3.64 mm Al Equivalent
14x17 Tethered Cesium Digital Detector
Application: General radiology
​
Scintillator: Csl: T1 (direct vapor deposition) + reflective coating
​
Pixel Pitch: 143 µm
​
Pixels: 2448 x 2984 (approx. 7.3 million pixels)
​
Image Size: 14 x 17 in (35 x 43 cm)
​
A/D Conversion: 16 bit
​
Output Data: 16 bit grayscale tiff
​
Preview Image Access Time: Approx. 4 seconds after x-ray exposure
​
MTF (2LP/MM): 36% typ
​
DQE (0): 70% typ
​
Power (Voltage/Frequency): AC 100-240 V 50/60 Hz
​
Operation Environment: Sensor Unit: 50-95° F (10-35° C), 10-85% RH (non-condensing)
​
Dimensions: Sensor Unit : 384 x 460 x 15 mm
​
Weight: Sensor Unit : 6.6 lb (3 kg)
​
Standard Components: Sensor Unit, Interface Box, Cables